Mostrar el registro sencillo del ítem
Comparación de propiedades físicas y mecánicas del hormigón tradicional y el hormigón con fibras metálicas recicladas
dc.contributor.author | Huamán Changa, Marilyn Del Rosario | |
dc.contributor.author | Rodríguez Gozar, Talia Mayra | |
dc.contributor.author | Díaz Garamendi, David | |
dc.date.accessioned | 2024-07-25T21:30:08Z | |
dc.date.available | 2024-07-25T21:30:08Z | |
dc.date.issued | 2022-07-01 | |
dc.identifier.citation | Huamán Changa, M. D. R., Rodríguez Gozar, T. M., & Díaz Garamendi, D. (2022). Comparación de propiedades físicas y mecánicas del hormigón tradicional y el hormigón con fibras metálicas recicladas. Gaceta Técnica, 23(2), 23-37. https://doi.org/10.51372/gacetatecnica232.3 | en_US |
dc.identifier.govdoc | pp 1999907LA2 | |
dc.identifier.govdoc | ppi201602LA4730 | |
dc.identifier.issn | 1856-9560 | |
dc.identifier.issn | 2477-9539 | |
dc.identifier.uri | http://bdigital2.ula.ve:8080/xmlui/654321/15171 | |
dc.description | Agradecimientos: Agradecemos a la empresa privada SMF Sagitario por permitirnos obtener la escoria de acero de los tornos de la institución, como también a Ecoandina Laboratorios SAC por realizar los análisis de compresión y tracción. | en_US |
dc.description.abstract | El presente estudio tiene como finalidad determinar las propiedades físicas y mecánicas del hormigón con virutas de acero de grado ASTM A36, y realizar un estudio comparativo con el hormigón tradicional. Se tuvo como muestra 36 probetas y se utilizó la viruta de acero en 0,6%, 1,5 y 6% como agregado fino. La viruta se obtuvo de los tornos de la empresa SMF Sagitario en la Ciudad de Lima. El diseño de la investigación es cuasi experimental y de corte longitudinal, la técnica de recolección de datos fue la observación. Se utilizó la estadística inferencial para la constatación de hipótesis, donde los resultados indicaron que hay diferencias significativas entre el hormigón tradicional y el hormigón con agregado fino (Sig.=.000). Concluyéndose que el hormigón tradicional es superior a en resistencia a la compresión y tracción realizadas a los 7, 14 y 28 días de edad. | en_US |
dc.description.abstract | The purpose of this study is to determine the physical and mechanical properties of concrete with ASTM A36 grade steel shavings, and to carry out a comparative study with traditional concrete. 36 specimens were taken as a sample and steel shavings were used at 0,6%, 1,5 and 6% as fine aggregate. The chip was obtained from the lathes of the company SMF Sagitario in the City of Lima. The research design is quasi-experimental and longitudinal; the data collection technique was observation. Inferential statistics were used to verify the hypothesis, where the results indicated that there are significant differences between traditional concrete and concrete with fine aggregate (Sig.=.000). Concluding that traditional concrete is superior to compressive and tensile strength at 7, 14 and 28 days of age. | en_US |
dc.description.sponsorship | Financiamiento: El presente trabajo de investigación fue 100% autofinanciado por las investigadoras. | en_US |
dc.language.iso | es | en_US |
dc.publisher | Universidad Centroccidental Lisandro Alvarado | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/ve/ | en_US |
dc.subject | Escoria de acero | en_US |
dc.subject | Resistencia a la compresión | en_US |
dc.subject | Resistencia a la tracción | en_US |
dc.subject | Hormigón con agregado fino | en_US |
dc.subject | Mezclas de hormigón | en_US |
dc.subject | Steel slag | en_US |
dc.subject | Compressive strength | en_US |
dc.subject | Tensile strength | en_US |
dc.subject | Fine aggregate concrete | en_US |
dc.subject | Concrete mixtures | en_US |
dc.title | Comparación de propiedades físicas y mecánicas del hormigón tradicional y el hormigón con fibras metálicas recicladas | en_US |
dc.title.alternative | Comparison of physical and mechanical properties of traditional concrete and with recycled metal fibers | en_US |
dc.type | Article | en_US |