dc.description.abstractObjetivo: Analizar las complicaciones post tratamiento de fracturas craneofaciales. Método: Descriptiva documental. Conclusión: Se pudo determinar que existe variedad de complicaciones en los tratamientos realizados en pacientes con fracturas cráneo faciales. Las características anatómicas del tercio medio facial justifican la frecuencia y su repercusión de estas fracturas. En los pacientes intervenidos se utilizaron miniplacas o malla con tornillos de titanio, o ambos elementos, asociados o no a material osteo conductor. El material de síntesis, construido de titanio es insoluble en el organismo, altamente resistente a la corrosión, inerte y biocompatible. Tanto el continuo perfeccionamiento de la técnica como la mejoría en los cuidados postoperatorios se asocian a una menor estancia hospitalaria de los pacientes y menos falla del tratamiento.en_US
dc.description.abstractObjective: To analyzepost-treatment complications of craniofacial fractures. Method: Descriptive documentary study. Conclusion: It was possible to determine that there is a variety of complications in the treatment of patients with craniofacial fractures. The anatomical characteristics of the middle third of the face justify the frequency and repercussions of these fractures. Miniplates or mesh with titanium screws, or both elements, associated or not with osteoconductive material, were used in the patients treated. The synthetic material, made of titanium, is insoluble in the body, highly resistant to corrosion, inert and biocompatible. Both the continuous improvement of the technique and the improvement in postoperative care are associated with a shorter hospital stay for patients and less treatment failureen_US
dc.language.isoesen_US
dc.publisherFUNDACIÓN KOINONÍAen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/en_US
dc.subjectFijación interna de fracturasen_US
dc.subjectfracturas cerradasen_US
dc.subjectrehabilitaciónen_US
dc.subjectFracture fixation internalen_US
dc.subjectfractures closeden_US
dc.subjectrehabilitationen_US
dc.titleComplicaciones post tratamiento de fracturas craneofacialesen_US
dc.title.alternativeComplicaciones post tratamiento de fracturas craneofacialesen_US
dc.typeArticleen_US


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

http://creativecommons.org/licenses/by-nc-sa/3.0/ve/
Excepto si se señala otra cosa, la licencia del ítem se describe como http://creativecommons.org/licenses/by-nc-sa/3.0/ve/