Mostrar el registro sencillo del ítem
Efecto del fuego sobre la resistencia a tracción del acero de refuerzo en losas
dc.contributor.author | Bespin, Angel | |
dc.contributor.author | Pérez, Nerio | |
dc.contributor.author | Martínez, Edson | |
dc.contributor.author | Scola, Salvador | |
dc.date.accessioned | 2020-01-09T14:16:25Z | |
dc.date.available | 2020-01-09T14:16:25Z | |
dc.date.issued | 2018-04 | |
dc.identifier.govdoc | pp 92.0200 | |
dc.identifier.issn | 1316-6832 | |
dc.identifier.uri | http://bdigital2.ula.ve:8080/xmlui/654321/3921 | |
dc.description.abstract | En el presente trabajo se evaluó el comportamiento del acero de refuerzo en losas nervadas bajo la acción del fuego, variando el espesor del recubrimiento, estudiando la resistencia a tracción del acero de refuerzo positivo. Se construyeron 9 modelos de losas nervadas de dimensión 50cm 70cm 20cm variando el espesor de recubrimiento en 1, 3 y 5 centímetros; adicionalmente se ensayaron 6 probetas de acero 3 de ellas se sometidas a fuego de forma directa, mientras las otras 3 se dejaron de patrón con el fin de establecer comparaciones en la resistencia a tracción. Todas las losas se sometieron a fuego constante durante 60 min a una temperatura mayor a 400°C para luego extraer el acero de refuerzo y ensayarlas a tracción. Los resultados arrojaron un excelente comportamiento del concreto como aislante, ya que se obtuvieron diagramas de esfuerzodeformación similares entre todas las probetas ensayadas. | en_US |
dc.description.abstract | This paper resume the results of the evaluation of the slabs steel reinforcement performance under the fire action, with the variation of the bar recoverment, studying the positive reinforcement steel tensile resistance. 9 slabs models were elaborated with 50cm 70cm 20cm dimensions, with 1, 3 y 5 centimeters of concrete recoverment ; additionally 6 steel bars were tested, 3 of them were directly exposed to fire, and the rest were non fire exposed and were used like a model reference to compare the obtained tensile resistance. Every slabs were exposed to fire for 60 minutes, heated over a 400°C temperature, after that the steel bars were extracted and tested. The results showed an excellent performance of the concrete like an isolating material, because all of the tested bars showed a similar stress-deformation diagram. | en_US |
dc.language.iso | es | en_US |
dc.publisher | Universidad de Carabobo | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/ve/ | en_US |
dc.subject | acero de refuerzo | en_US |
dc.subject | losa | en_US |
dc.subject | exposición al fuego | en_US |
dc.subject | resistencia a la tensión | en_US |
dc.subject | steel reinforcement | en_US |
dc.subject | slab | en_US |
dc.subject | fire exposition | en_US |
dc.subject | tensile resistance | en_US |
dc.title | Efecto del fuego sobre la resistencia a tracción del acero de refuerzo en losas | en_US |
dc.title.alternative | Fire effect on the tensile resistance of slabs steel reinforcement | en_US |
dc.type | Article | en_US |