dc.description.abstractLa medición de la presión intra -abdominal (PIA) es un procedimiento médico realizado por lo general en unidades de cuidados intensivos, y asociado a las manifestaciones clínicas del paciente permite diagnosticar la falla de los diferentes órganos y sistemas. La presión intra-abdominal es un parámetro único que permite decidir conducta tanto médica como quirúrgica ya que si se realizara como procedimiento de rutina, en pacientes a quienes se someten a intervención quirúrgica o sufren de patología medica con afectación de la cavidad abdominal, la PIA nos indica el estado de la cavidad abdominal permitiendo así decidir cuándo realizar laparotomía exploratoria y evitar la disfunción de órganos y sistemas. Objetivo: Establecer los valores normales de presión intra-abdominal en neonatos sanos del Hospital Universitario Pedro Emilio Carrillo en el período enero 2015 marzo 2016. Metodología: La investigación fue de tipo exploratoria, prospectivo, Población censal, muestreo no probabilístico intencional. La población estuvo representada por todos los pacientes que se encontraron hospitalizados en el servicio de la UNEC del hospital central de Valera período enero 2015 marzo 2016 y la muestra estuvo conformada por un total de 341 pacientes siendo 206 sexo masculino y 135 sexo femenino Resultados: Total de pacientes estudiados fue 341; correspondiendo 135 (39,59%) al sexo femenino y 206 (60,41%) al sexo masculino. Las edades de los pacientes estudiados tiene el porcentaje Mayor de 75,07%, comprendido el intervalo de 0-3 días, siendo el del menor porcentaje con un 0,59 % el intervalo de edad de 16-18 días. El valor de presión intra-abdominal en neonatos a término con peso que oscila 2,00 kg a 4,00 kg, ambos sexos sin patología agregada oscila de 5 a 10 mmhg en reposo y 10 a 17 mmhg en estado activo.Conclusión: Existe variación de presión intra-abdominal en estado activo y reposo con una diferencia de 6 mmhg aproximadamente. No existe variación de los valores de presión intra-abdominal por peso, edad ni sexo.en_US
dc.description.abstractThe measurement of intra-abdominal pressure (IAP) is a medical procedure performed usually in intensive care units, and associated with the clinical manifestations of the patient to diagnose the failure of various organs and systems Intra-abdominal pressure is a parameter All you can decide both medical conduct as surgical as if performed as a routine procedure in patients who undergo surgery or suffer from medical pathology with involvement of the abdominal cavity, the PIA indicates the state of the abdominal cavity allowing decide when to perform exploratory laparotomy and prevent organ dysfunction and systems. Objective: To establish normal values of intra-abdominal pressure in healthy infants in the University Hospital Pedro Emilio Carrillo in the period January 2015 March 2016 Methodology: The research was intentional exploratory, prospective, population census, non-probability sampling. The population was represented by all patients were found hospitalized in the service of the UNEC the central hospital of Valera period January 2015 March 2016 and the sample consisted of a total of 341 patients being 206 male and 135 female Results: Total patients studied was 341; corresponding 135 (39.59%) and female sex 206 (60.41%) to masculine. Las sex age of patients studied has the highest percentage of 75.07%, including the range of 0-3 days, still the lowest percentage with 0.59% the age range of 16-18 days. The value of intra-abdominal pressure in term infants with weight ranging 4,00 kg 2,00 kg to both sexes without added pathology ranges from 5 to 10 mm Hg and 10 mm Hg at rest to 17mhg in active. Conclusions: There is intra-abdominal pressure variation in active and idle state with a difference of 6 mmhg. No there is variation of the values of intra-abdominal pressure by weight, age or sex.en_US
dc.format.extentviii, 34 hojasen_US
dc.language.isoesen_US
dc.publisherUniversidad de Los Andes, Facultad de Medicina, Hospital Universitario Dr. Pedro Emilio Carrillo, Postgrado de Cirugía Pediátrica y del Adolescenteen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/en_US
dc.subjectPresión intrabdominalen_US
dc.subjectSíndrome compartimentalen_US
dc.subjectNeonatosen_US
dc.subjectEnfermedades del abdomenen_US
dc.subjectIntra-abdominal pressureen_US
dc.subjectCompartment syndromeen_US
dc.subjectNeonateen_US
dc.titleValores normales de presión intrabdominal en neonatos sanos del Hospital Universitario "Pedro Emilio Carrillo"en_US
dc.title.alternativeNORMAL VALUES IN NEWBORNS intra-abdominal pressure HEALTHY UNIVERSITY HOSPITAL "PEDRO EMILIO CARRILLO" PERIOD JANUARY 2015 MARCH 2016en_US
dc.typeThesisen_US