Mostrar el registro sencillo del ítem

dc.contributor.advisorMagali, Yanni Ariza
dc.contributor.authorTorrez Romero, Diomar José
dc.contributor.otherRamirez, Rosmary
dc.contributor.otherFranco Soto, José Vicente
dc.contributor.otherPimentel, Alicia
dc.contributor.otherMora, Carmen
dc.date.accessioned2022-06-03T15:16:43Z
dc.date.available2022-06-03T15:16:43Z
dc.date.issued2019-10-08
dc.identifier.urihttp://bdigital2.ula.ve:8080/xmlui/654321/7368
dc.descriptionEspecialista en Puericultura y Pediatríaen_US
dc.descriptionCota : RJ276 T6en_US
dc.descriptionBiblioteca : Tulio Febres Cordero (siglas: eub)en_US
dc.description.abstractLa ictericia neonatal es un proceso fisiológico secundario a la inmadurez hepática y aumento en la producción de bilirrubina, con un cuadro clínico auto limitado que por lo regular no requiere tratamiento.1 La observación clínica que realizamos inicialmente en el recién nacido; y a su vez midiendo el valor de bilirrubina con el bilirrubinometro transcutaneo en lugar de solicitar valores séricos de la misma, parece ser una opción razonable para tener un valor de bilirrubina inicial. La presente investigación es un estudio analítico, observacional, transversal, y prospectivo, en este estudio se obtuvo información directamente de los pacientes recién nacidos ingresados con diagnóstico de ictericia en el Hospital Central de San Cristóbal 2019. La muestra estuvo conformada por 50 neonatos los cuales fueron ingresados en área de UPN y URN en el Hospital Central de San Cristóbal con diagnóstico de ictericia neonatal. Los datos se recogieron y se analizaron mediante el programa IBM SPSS statistics 22 mediante la prueba estadística índice de Kappa de Cohen entre el valor de la bilirrubina transcutanea BiliCare® y sérica la medida de acuerdo a Kappa resulto de 0.68 la cual se encuentra en el nivel de buena concordancia entre ambas pruebas diagnósticas, según los resultados que obtuvimos se recomienda este dispositivo de medición el cual es un método útil que nos orienta y permite reducir el número de pruebas invasivas, hospitalizaciones innecesarias, reduciendo así los costos que amerita para la institución y familiaresen_US
dc.description.abstractNeonatal jaundice is a physiological process secondary to hepatic immaturity and increased bilirubin production, with a self-limiting clinical picture that usually does not require treatment.1 The clinical observation we performed initially in the newborn; and in turn measuring the value of bilirubin with the transcutaneous bilirubinometer instead of requesting serum values of it, it seems to be a reasonable option to have an initial bilirubin value. The present investigation is an analytical, observational, cross-sectional, and prospective study. In this study, information was obtained directly from newborn patients admitted with a diagnosis of jaundice in the Central Hospital of San Cristobel 2019. The sample consisted of 50 infants who they were admitted to the UPN and URN area at the Central Hospital of San Cristobel with a diagnosis of neonatal jaundice. The data was collected and analyzed using the IBM SPSS statistics 22 program by means of the Cohen Kappa index statistical test between the value of bilirubin transcutaneous BiliCare® and serum measured according to Kappa resulting from 0.68 which is at the level of good concordance between both diagnostic tests, according to the results obtained we recommend this measurement device which is a useful method that guides us and allows us to reduce the number of invasive tests, unnecessary hospitalizations, thus reducing the costs that merit for the institution and familyen_US
dc.format.extentvi, 33 hojasen_US
dc.language.isoesen_US
dc.publisherUniversidad de Los Andes, Facultad de Medicina, Post Grado de Puericultura y Pediatríaen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/en_US
dc.subjectIctericiaen_US
dc.subjectBilirrubinometro transcutaneoen_US
dc.subjectKappa de Cohenen_US
dc.subjectHiperbilirrubinemiaen_US
dc.subjectJaundiceen_US
dc.subjectTranscutaneous bilirubinometeren_US
dc.subjectKappa de Cohenen_US
dc.titleUtilidad del bilirrubinómetro transcutáneo en el diagnóstico de ictericia neonatal en el área de recien nacidos : Hospital Central de San Cristóbal 2019en_US
dc.typeThesisen_US


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

http://creativecommons.org/licenses/by-nc-sa/3.0/ve/
Excepto si se señala otra cosa, la licencia del ítem se describe como http://creativecommons.org/licenses/by-nc-sa/3.0/ve/