Mostrar el registro sencillo del ítem

dc.contributor.advisorRojas de Betancourt, María Alicia
dc.contributor.authorPérez Caraballo, María Viriginia
dc.contributor.otherRivas, Pedro
dc.contributor.otherLópez, Marcos
dc.date.accessioned2022-12-07T16:00:10Z
dc.date.available2022-12-07T16:00:10Z
dc.date.issued2012-10-10
dc.identifier.urihttp://bdigital2.ula.ve:8080/xmlui/654321/9833
dc.descriptionCota : RE339 P47en_US
dc.description2012en_US
dc.descriptionEspecializaciónen_US
dc.descriptionBiblioteca : Tulio Febres Cordero (siglas: eub)en_US
dc.description.abstractEl queratocono anterior forma parte de las distrofias ectásicas de la córnea, cuya importancia radica en la incapacidad visual hacia la cual progresa. Típicamente el paciente manifiesta visión borrosa o distorsión de las imágenes. Su complejo tratamiento nos lleva a emplear todos los recursos humanos y tecnológicos disponibles para el diagnóstico precoz de queratocono. Para la presente investigación se planteó relacionar factores de riesgo, valores de queratometría elevada, espesor corneal y topografía cornea! con la presencia o no de queratocono. Se realizó un estudio descriptivo correlacional, donde a todo paciente que presentó una queratometría igualo mayor a 45 D en su K mayor, se les realizó paquimetría y topografía corneal. La muestra estuvo representada por 30 pacientes, 24 de los cuales pertenecían al género femenino, la mayoría (43,3%), habitaban en la ciudad de Mérida; el 43,1% resultaron con algún grado de queratocono, donde el 22,4% estaban en queratocono grave. No se encontró correlación entre el diagnóstico y los antecedentes tanto generales como oculares. Los resultados mas resaltantes se vieron reflejados en los valores de las medias de las queratometrías en el grupo de Astigmatismo regulares (46,55 D) y Queratocono Leve (46,51 D). En conclusión se recomienda usar paquimetría y topografía cornea! en todos los pacientes con queratometrías igual a la media encontrada en esta investigación para poder diferenciar entre ambas patologías. De esta manera se lograría tener un diagnóstico temprano del queratocono e iniciar el tratamiento específico.en_US
dc.description.abstractAnterior keratoconus is an ectasic disorder of the cornea, it is importance is the visual impairment that progresses. Tipically the patient complains of blurry vision or image distorsiono In this investigation risk factors, high keratometries values, pachymetry and corneal tophography were related with the diagnostic of keratoconus. A descriptive, correlational study was carried out pachymetry and corneal tophography in patients with keratometry > 45D (highest K). 30 patients were included in this study (24 female), most of them were from Mérida (43,3%). 43, 1% were classified as mild keratoconus and 22,4% were severe keratoconus. There was not a correlation between general or ocular diseases and the diagnosis. The most important result were the media of the keratometries of regular astigmatism (46,55 D) and mild keratoconus (46,51 D). In conc!usion pachymetry and corneal tophography should be done to every patient with queratometry values > to the media stablished in this investigation, which allows to make an earlier treatment.en_US
dc.language.isoesen_US
dc.publisherUniversidad de Los Andes, Facultad de Medicina, Instituto Autónomo Hospital Universitario de Los Andes, Postgrado de Oftalmologíaen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/en_US
dc.subjectQueratoconoen_US
dc.subjectEnfermedades de la córneaen_US
dc.subjectEnfermedades de la córneaen_US
dc.subjectTopografía cornealen_US
dc.subjectAstigmatismoen_US
dc.subjectQueratometríaen_US
dc.subjectEspesor cornealen_US
dc.subjectKeratoconusen_US
dc.subjectAstigmatismen_US
dc.subjectKeratometryen_US
dc.subjectPachymetryen_US
dc.subjectCorneal Topografyen_US
dc.titleQueratometría y espesor corneal relacionadas con astigmatismo y queratocono en pacientes que asisten a la consulta de oftalmología del Instituto Autónomo Hospital Universitario de Los Andesen_US
dc.typeThesisen_US


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

http://creativecommons.org/licenses/by-nc-sa/3.0/ve/
Excepto si se señala otra cosa, la licencia del ítem se describe como http://creativecommons.org/licenses/by-nc-sa/3.0/ve/